KVV22 Electrical Cable Control Heavy Copper Core Flexible Fire Resistant Electric Wire Cable

PVC insulated PVC sheathed control cable is suitable for wiring of control, signal, protection, and measurement systems with rated voltage of 450/750V and below or 0.6/1kV and below.

Products Details

Scope of Application: PVC insulated PVC sheathed control cable is suitable for wiring of control, signal, protection, and measurement systems with rated voltage of 450/750V and below or 0.6/1kV and below.

Control Cable

Model KVV, KVV22, KVVP, KVVR, KVVRP, ZRKVV, ZRKVV22, ZRKVVP, ZRKVVR, ZRKVVRP
Specification 2 x 1~72 x 4 mm²
Rated Voltage The power frequency AC rated voltage is 450/750V, and the maximum voltage of the AC system should not exceed 1.0KV.
Working Temperature ℃ When the long-term allowable maximum working temperature of the cable conductor is 700°C, the maximum temperature of the cable conductor is 160°C, and the duration does not exceed 5 second.
Ambient Temperature ℃ Minimum ambient temperature for cable operation - 15℃.
Laying Temperature When installing and laying, the temperature should not be lower than 0°C.
Bending Radius The minimum bending radius should not be less than 6 times the outer diameter of the cable.
Laying Drop When laying, it is not limited by the drop.
Model Name Voltage (V) Number of Cores Section (mm²) Main Scope of Application
KVV Copper core PVC insulated PVC sheathed KVV cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipelines, and other fixed occasions
KVV22 Copper core PVC insulated PVC sheathed steel tape armored KVV22 cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipelines directly buried and other fixed occasions that can withstand large mechanical external forces
KVVP Flame retardant copper core PVC insulated PVC sheathed KVVP cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipes and other fixed occasions requiring shielding
KVVR Copper core PVC insulated PVC sheathed control flexible cable 450/750 4~37 0.75~10 Laying indoors, where there are mobile requirements
KVVRP Copper core PVC insulated PVC sheathed braided shielded control flexible cable 450/750 4~37 0.75~10 Laying indoors, where there is a requirement for mobile shielding
ZRKVV Flame retardant copper core PVC insulated PVC sheathed ZRKVV cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipes and other fixed occasions requiring flame retardant
ZRKVV22 Copper core PVC insulated PVC sheathed braided steel tape armored ZRKVV22 cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipelines directly buried and other fixed occasions that can withstand large mechanical external forces and have flame retardant requirements
ZRKVVP Copper core PVC insulated PVC sheathed braided shield ZRKVVP cable 450/750 4~37 0.75~10 Laying indoors, cable trenches, pipes and other fixed occasions requiring shielding and flame retardant
ZRKVVR Copper core PVC insulated PVC sheathed braided ZRKVVR cable 450/750 4~37 0.75~10 Laying indoors, where there are mobile and flame retardant requirements
ZRKVVRP Copper core PVC insulated PVC sheathed braided shield ZRKVVRP cable 450/750 4~37 0.75~10 Laying indoors, where mobile shielding and flame retardant requirements are required

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours